About this release

For version information, please refer to About in Preferences.

Release 2.6.0

Date 24th March 2025

New Features:

Mosaic Support 

  • Device detection (Mosaic) 

    • Automatic detection of Mosaic device from Device Hub & Display information device in Device Hub

    • Detection and control of mosaic diode laser

    • Control of mosaic illumination area includes full area and bit map

  • Calibration

    • Fully automated 'one click' calibration of Mosaic device

    • Automatically detect the usable illumination area of the Mosaic and visualise to user using photostimulation bounds and toggle on/off

      • Regions that fall partially or wholly outside the Mosaic illumination area will be clipped to only illuminate the portion within the field

    • Calibration applies at the Mosaic device level and may be used for both:  1) camera used for the calibration and 2) the other camera in the system.

Regions and region management

  • Photostimulation region management

o    Regions can be tagged as either photostimulation or analysis.

o    New Overlay manager, which includes possibility to 1)  save load and export regions, 2) rename regions

o    Photostimulated overlays appear as recorded regions on the acquired image. These can be cloned as Analysis and/or Photostimulation overlay types for reuse

o    Recorded Regions are shown for each associated photostimulation event so it is clear where and when photostimulation took place during the acquisition of image data ,and can be toggled on/off for visualisation.

o    Support for saving the acquired time point / frame position to .roi files for use in Fiji

 

Photo Stimulation protocols

  • Trigger

    • Mosaic illumination time can be configured in channel settings

    • Mosaic device can be illuminated as part of a protocol trigger

    • Trigger can be configured to 1) fire at equally spaced time points after the initial trigger time point of the protocol, 2) add delay in the protocol.

    • BOB Output 6 can be used as a trigger in the protocol. (The spare output on the Bob device can be configured to pulse at the start of a specified timepoint during a protocol)

  • Manual Triggering

    • All protocol triggers can be manually fired with one click if desired

    • Each trigger that is configured in the active protocol can be triggered manually on demand

    • Allow Automatically move (skip) a running protocol to the next time point if the user manually fires one of its triggers

  • Regions within protocols

    • Phostimulation protocols with mosaic are possible and require the use of phostimulation regions and triggers.

  • Review photostimulation protocol

    •  The timepoints at which photo stimulation occurred is displayed on the image navigation bar

    •   Region manager panel added this lists all current regions with name and type

 

  Analysis

  • Through series analysis supports overlays.

  • Through series analysis has a progress bar on the start/stop button.

  •   Through series analysis will automatically switch to Time Series or Z Scan where applicable.

 

  Drift Stabilisation 

  •   Ability to automatically remove drift stabilisation dichroic mirror during a protocol for supported devices

  • Move Dichroic Mirror Out when Drift Disabled for Leica DMi8

  • Move Dichroic Mirror Out when Drift Disabled for Nikon Ti2

  • New protocol setting to control whether dichroic moves out when drift is disabled 

  •  Support removing drift stabilisation dichroic mirror in time series for Leica DMi8

  •  Support removing drift stabilisation dichroic mirror in time series for Nikon Ti2 

  • Updated drift stabilisation tooltips to be more informative

 

Other Improvements

  • Adds the ability to play sounds at key events during Fusions runtime

  • Added some 3rd party libraries to the Acknowledgements dialog

 

Bug Fixes

  • Fixed a crash related to trying to validate devices that have not finished connecting

  • Fixed crash when running a quick montage if the Montage bounds were not set.

  • Fixed Snap Live to ignore different channel settings.

  • Fixed Updating Z range using slider does to update start/end values properly

  • Fixed issue where clicking on a deconvolved image would cause the live images to overwrite the previous images.

  • Fixed deconvolution parameters reset on acquisition.

  • Fixed Image zoom on the mouse location when using the scroll wheel.

  • Fixed issue where Position and Intensity were not updated on Zoom in/out event when mouse not moved.

  • Fixed issue when position and intensity was not updated on zoom in/out on image display.

  • Scroll bars are now enabled when Fusion is Acquiring or Live 

  • Fixed "save image" dialog appearing when going Live, if user double clicked during a previous acquisition

 

Limitations to Photostimulation Protocols

  • Different illumination sources cannot be assigned to specific regions in this release

  • Sequential illumination of regions is not possible in this release.

Release 2.4.0.22 (Patch 1)

30th July 2024 

Bug Fixes:

  • Fixed issue where settings were grouped and moved to incorrect locations.

  • Fixed issue where empty filters displayed as magenta instead of grey.

  • Fixed issue for incorrect reporting of voxel size. 

  • Fixed issue causing software slowdown/freeze when "Show full dynamic range of camera" is on. 

  • Fix for active iXon shutter when using HLE shutter.

  • Fix for dual ILE laser engines connection.

  • Fix for BTIRF Optical Feedback not in sync with BTIRF Fine Adjust slider.

  • Fix to allow 384 well plate configuration as part of sample holders.

Release 2.4

23rd January 2023

New Features:

Control of High Power Laser (Super Resolution functionality) & B-TIRF functionality

  • Ability to control High Power Laser (HLE) with power level multipliers.

  • Support of/for HLE Burst Shutter functionality for high power laser.

  • Added Z-Scan option to 'Finite Burst' Protocol type (with static Z-Scan Acquisition Order).

  • Option added to save each 'Finite Burst' time series at each specified Z-Scan position to its own separate file (with an '_Z' suffix).

  • Added drift stabilisation to 'Finite Burst' protocol type with Leica AFC and Nikon Ti2 PFS systems.

  • Acquisition & control for Borealis-TIRF (B-TIRF) functionality.

Acquisition improvements

  • Piezo z position is displayed in the multi-field table.

  • Option added to the drift stabilisation protocol settings: enable drift stabilisation when recording a field in the multi-field table

  • Option to add a post-trigger delay to triggers.

  • SRRF-Stream+ algorithm improvement: removal of 'donut' shaped artefact on spot-like features.

Visualization improvements

  • Easier moving and resizing of small regions. 

  • Image frame timestamp resolution increased to microseconds.

  • Taskbar icon reflects protocol status and state now including Deconvolution and Stitching.

  • Contrast level is stored per image.

Other improvements

  • Saving Z calibration information for all acquisition types using the information from microscope and Piezo position.

  • Disk Rotation On/Off  option to allow alignment of dual cameras. Dual camera alignment Instructions now included in Dragonlfy hardware manual.

  • Prevent Windows Update and User logout from shutting down Fusion while an acquisition is in progress.

  • HLE burst shutter timing threshold can be set by customer support.

Bug Fixes:

Acquisition bug fixes

  • Fix Fusion crash when running Finite Burst with Frame Average.

  • Fix for crash when editing the imaging mode.

  • Fixed crash when loading an image file from the root folder.

  • Fix to prevent crash of Fusion during long protocols with multiple channels

  • Fix ASI stage communication timeouts caused by transient errors.

  • Fix acquisition failing to resume after being paused.

  • Fix Fusion freeze when attempting a second run of a 3 channels montage.

  • Fix added to prevent images not being deleted when stopping a protocol before completion

  • Error message is now displayed if the image file path length exceeds the Windows maximum limit. Protocol won´t run until file path name is corrected (shortened).

  • Fix for Z scan size not updating correctly after maximum and minimum values are set for Analogue Piezo Z.

  • Fix for multi position acquisition slow down or hang.

  • Fix erroneous report of Zyla camera acquisition mode (finite burst protocol). Previously Fusion reported the acquisition was in external mode, while acquisition was running in internal mode.

  • Fix incorrect calculation of Finite Burst duration.

  • Fix for readout time not updating when acquisition settings changed.

  • Fix for slow acquisition start time when drift stabilisation is enabled on an IX83 microscope.

  • Fix for wells that have been added appearing as red in the multifield table with an iX83 stage

Deconvolution & stitching bug fixes

  • Fix for Fusion crashes when opening deconvolved image in split-channel MIP

  • Fix for deconvolution crashing when trying to load images where the first file in the dataset is missing

  • Fusion now prevents Windows OS shutdown while deconvolution and/or stitching processing are active

  • Fix for deconvolution slow down.

  • Fix deconvolution estimated time updates. When deconvolution is activated through the estimated time is now updated.

  • Fix for deconvolution preview window closing when clicked.

  • Fix stitching error when commas used as decimal separators.

Other bug fixes

  • Device Features for different devices of the same type are now grouped under the particular device they correspond to.

  • Fix to ensure all compatible channels can be merged or linked in dual camera simultaneous acquisition.

  • Fix for null control Unicode character in channel config files.

  • Fix for features being updated by other devices of the same type.

  • Changed the default device alias of laser controllers from "Light Source" to "Laser"

  • Improved the text error message displayed when all the fields in a table are deleted.

  • Fix for reading incorrect Objective Numerical Aperture value.

  • Fix to prevent invalid configuration files causing unsuccessful initialisation of Fusion

  • Fix for Calibration Warning not disappearing when Optical Magnification is equal for all Channels

  • Improve synchronisation of dual camera externally triggered finite burst protocols by removing delays introduced at the start of the protocol.

  • During a fast finite burst (faster than 10 Hz), leave the mechanical shutter open on laser.

  • Laser power management improved: when switching channels, lasers not in use are turned off, and then new lasers are turned on.

  • The number of log files retained has been increased to 20.

Release 2.3.0.44 (Patch 1)

Date 11th October 2021

Enhancements

  • Added Simulated Global Shutter Clear feature for Sona cameras, to simplify synchronising the camera fire output with the confocal disk rotation.

  • Faster Tiff Export with upgrade of Imaris Library.

  • Default temperature for Sona camera changed to 0C.

  • Support for Silicone objectives with a Ti-E microscope.

Bug Fixes

  • Fix for crash on application start-up or when changing channel due to very large exposure times being stored in the configuration files.

  • Fix for hang of application when importing a protocol from an image.

  • Fix for "Collection was Modified" error message and crash when running acquisitions.

  • Fix for Dragonfly 200 Filter Mode not being shown.

  • Fix for 384 well plate not displaying properly. (384 well plate configuration is available on request)

  • Smooth Auto-Map Enable preference tool tip fixed.

  • Fix for crash after importing a protocol that contains a Bone or other predefined lookup table.

  • Fix for cache folder getting corrupted when 'Write directly to file' is switched off.

  • Deconvolution does not begin until a protocol is complete (to avoid acquisition data loss if any issues arise during deconvolution). This option can be overridden in preferences.

Release 2.3.0.36

26th April 2021

Multidimensional / Multi-well acquisition

  • Support for Multiwell plates in Multifield protocol

  • Graphical drag-to-select in Multiwell Scan setup

  • Montage enabled in multifield and Multiwell scanning

  • Stitcher now supports multifield datasets.

  • New Sample Holder menu in the remote panel to allow Multiwell plate selection.

  • Stitch each montage of a multifield protocol into a single dataset.

  • New manual calibration for Multiwell plates

  • Montage at each field position now saves each Montage into a separate folder

AutoFocous / PSF improvemnts

  • Improved reliability of Leica AFC over long protocol runs – requires DMi8 firmware update.

Visualization improvements

  • Improved histogram analysis for default Automap

  • Progressive multi-click Max-Min settings for Automap. 

  • Multi image display with automatic mode switching when performing preview montages

  • New navigation slider to review Montage per Field

Enhancements:

  • Update to SDK3 libraries to address issues when acquiring over 1000 fps

  • Recover and continue the acquisition if a fault occurs on a sCMOS camera.

  • Upgrade of Imaris Rendering Engine to 9.6

  • Upgrade of Imaris Stitching to 9.6 to fix shadowing in stitched output.

  • Event Tags can now be visualised in Imaris

  • Update Multifield rendering to handle overlapping frames better

  • Automatic dump when user interface hang detected

  • New problem notification when incorrect NUMA settings detected

  • Problem notification to alert user when camera port is unassigned.

  • Control of DEBUG logging level output

  • Deconvolution – enable/disable auto-populate option for PSF Settings (user request)

Bug Fixes

  • Incorrect loop interval unit of measure.

  • Z step too slow for PIFOC 2000um in Fusion.

  • Fix for zeros in preview stitch causing bad mapping.

  • Crash on Fusion start up if speech recognition fails to initialise.

  • Fusion crash when ILE exceeds power limit while started in low power mode.

  • Delay in protocol starting due to username lookups.

  • Finalizer error while running live with manual mapping window open.

  • Crash and disappearance of the application while running an acquisition.

  • Nvidia error causing Fusion to close on long time lapse.

  • Incorrect scan range used when using piezo-z in a multi field protocol.

  • Unable to overwrite stitched image.

Release 2.2.0.50 (patch)

15th October 2020

Enhancements

  • Support for control of Dragonfly 3D Single Molecule feature in all imaging modes.

  • Added support for setting a manual settle time for PIFOC z movements.

Bug Fixes

  • Fix for TIRF feature merge problem notifications appearing when merged channels are using a non-TIRF imaging mode.

  • Fix for crash when acquiring with frame averaging set above 1.

Release 2.2.0.49 (patch)

5th August 2020

Enhancements

  • Advanced Deconvolution Options:  re-added 'Minimum Intensity Removal' and 'Initial Denoising'.

  • Problem Notification warnings: Nyquist Sampling Criterion added option to remove the warning.

  • Dragonfly Magnification Correction feature can be modified while in customer support mode.

Bug Fixes

  • Fix slowdown in z movement and in z scan protocols when using the Leica DMi8 Reference Z. 

  • Fix for application freeze when running at short exposure times and improve general responsiveness.

  • Fix for duplicate channel names with different capitalisation crashing Fusion on start up.

  • Fix for application hang when aborting an acquisition while a stage move or other long running hardware setting update is in progress.

Release 2.2.0.38

20th May 2020

Enhancements

SRRF Stream

  • Users with the SRRF license will benefit from algorithm improvements.

  • Significant reduction in star artefact, especially on spot features.

  • Improved default settings require less user adjustment.

  • Optional fixed pattern noise (FPN) correction reduces background structure.

Improvements in Specimen Navigation

  • Redesign of the Navigation Panel.

  • Introduction of 3x3 Quick Tile Preview Montage.

  • Multi-field table double-click takes user to selected field position.

  • Next and Previous navigation buttons added to multi-field setup.

  • Offset All Fields added, with options for XY and XYZ values – helpful for removing/replacing slides on stage.

  • Iterate through all fields with delay, supports easy checking of fields.

Focus Drift Correction improvements

  • Nikon PFS4 improvements for focus tracking during montage and multi-field.

  • Control of Nikon Ti2 Z Drive Modes – closed-loop and precision settings.

  • Olympus - Options for loss of lock: “Use last known good position”, “request user intervention”, “stop protocol”.

Image annotation and overlays for analysis

  • Scale bar overlay for 2D image display modes.

  • Through Series Chart now plots counts against time stamp or z depth depending on the chart mode i.e. Time-Series/Z-Stack.

  • Through-Series Chart displays chart point details when mouse hovers over line plot.

File Management

  • Change filename on inactive datasets.

  • Option to discard the acquired data when stopping a protocol early.

  • Improvements relating to “Favourite” tools for file management and sorting.

  • Improvements to image data handling for robustness and performance.

Improvements in Stitching

  • Allow selection of image channel for alignment during stitching.

  • New Stitcher library updates for more robust performance.

  • Fix to Stitching when overlap regions doubled.

Deconvolution

  • Simplified Deconvolution Preview Interface.

  • Visualise and save the model 'PSF' generated in ClearView Deconvolution.

  • Improvements in block-wise management of very large datasets.

  • Improvement of synchronization during Protocol acquisition.

  • Addition of Nyquist Sampling Criterion check for current Protocol settings.

  • Addition of Nyquist Sampling Criterion check for Deconvolution.

  • Removal of 'GPU Processing Memory Limit' Preference – now automatic.

Acquisition and Device Control

  • Added support for the new Physik Instrumente digital PIFOC-2000 device.

  • "For each Channel, Acquire Z Stack" support for linked channels.

  • Support 7th Objective on Dummy/manual Scope.

  • Support 30x Objective on Dummy/manual Scope.

  • Auto-switch External mode on ASI Stage when selecting Analog Piezo control.

  • Allow manual triggering of protocol triggers from the Acquisition panel.

  • Faster Finite Burst performance for Zyla and iXon cameras.

Support of additional Olympus IX83 Microscope functionality.

  • Support for Olympus scope filters.

  • Support for Olympus z-escape.

  • Support for ZDC dichroic mirror.

  • Simplified Drift Stabilisation Feature Control.

Remote Control API (REST)

  • Extend and customize the capabilities of your system in an open framework.

  • Remotely control Fusion to execute protocols, set device features and more.

  • Synchronize and sequence external hardware e.g. microfluidics.

  • Supported by examples in Python, MatLab, LabView.

  • REST (REpresentational State Transfer) a is communication standard widely used on the world wide web.

  • Instructions and example code is available on request.

               

Service Page

  • We added a Service page into Fusion with local service telephone and email account contact details.

  • In future we will populate this page with useful tools for gathering system, licensing and debug information.

Bug Fixes

  • iXon EMGain Limited to 188 on restart.

  • Resolution of device communication issue leading to random dark frames.

  • Cannot open Fusion generated ims files in Fiji.

  • Crash reading dataset gallery configuration file.

  • Fusion installer is overwriting Imaris .ims file association.

  • Fix to possible corrupted configs.

  • Out of range drift offset values added to Multi field table.

  • Dataset channels get out of sync when a failure occurs in protocol.

  • Deconvolution during protocol not working when running a negative z scan.

  • Advanced Color picker not showing.

  • "Go To field" doesn't always work first time when drift stabilisation enabled.

  • Montage/Multifield table Goto button not re-enabling after bounds unlocked.

  • Finite burst slow down for non admin user.

  • Fusion crash during “Live”.

  • Explain external trigger time out so easy for user to understand.

  • Crash when adding a channel.

  • Timestamps in deconvolved dataset are incorrectly displaying time of deconvolution.

  • Fusion crash if expected buffer address not return when reading SDK3 acquisition device buffers.

  • Connected Sona "Metadata Enabled" feature becoming de-activated if searching for other SDK3 devices.

  • Recover and continue with protocol if iXon communication error occurs.

Release 2.1.0.80 (Hotfix)

 

28th March 2019

 

Enhancements

 

  • Offset XY or XYZ for multifield points.

  • Removal of the "Use Ref Z as" options from the multifield positions section (this is now implied by the scan mode in the Z scan settings).

  • Update all multifield Ref Z positions based on offset between current field hold position and ref z position.

Bug Fixes
  • Olympus IX83 stability improvements.

  • Z Scan scan size calculation correction for microscopes whose depth does not begin at 0μm.

  • Optical Magnification calculation corrected on startup for use with manual turrets.

  • Fix Nikon Ti2 crash when shutting down in Analysis mode.

  • Fix to use the active channel name instead of the protocol channel names in the file name of the image when performing a snap with 'Active Channel' selected.

  • Z stack range not tracking drift stabilization hold position when doing multi field z or single z protocols with drift stabilization enabled.

  • Fix for datasets with numerous channels not being able to be opened in ImageJ.

  • Fix for datasets with a large number of frames not being able to be opened in ImageJ.

  • Fix SDK3 camera crash when Metadata Timestamp feature is disabled.

Release 2.1

20th November 2018

Enhancements
  • Support of Manual MicroPoint

    • Number of Pulses Feature

    • Time Between Pulses Feature

    • Support of triggering at a specified time point

  • Support of Olympus IX83 Microscope

    • Objective control and awareness of objective magnification to allow measurements on the image

    • Support for 3D image acquisition using the Z drive and support for ClearView-GPU™ deconvolution processing 

    • Support of montage and multi field protocols using the XY Stage.

    • Support for switching the light path between camera port and eye piece.

    • Support of ZDC to maintain focus during acquisitions.

  • Support of Sona back-illuminated sCMOS camera

    • including SRRF-Stream™ support

  • Fixed-Pattern Noise correction in SRRF-Stream™ 

  • Support for HF-Boost Image Processing.

  • Improved ClearView-GPU™ deconvolution processing performance (up to twice as fast as previous release)

  • Simplified ClearView GPU™ deconvolution settings

  • Support for drift stabilisation during time series protocols with montage.

  • Support favourite images

  • Support for overwriting existing channels when importing a protocol

  • Improved file naming – support for protocol & channel names

  • Support for negative Z scans

Bug Fixes
  • Fix for incorrect emission filter in some default channels.

  • When performing background correction, the ALC Coherence setting is now the same as is used in the protocol.

  • Fix for crash on application start up when an image in the recent images list is not accessible to the current user.

  • Fix for crash on start-up of application when an imaging mode associated with a channel is missing.

  • Fix for error when renaming a protocol to a name that was a sub set of 'protocol'.

  • Fix for crash when exporting an image to a drive with insufficient space available.

  • Fix for crash on start-up of application when time repeat frequency is zero.

  • Fix for Acquire button being disabled when Drift stabilisation offset is invalid (-1) in a multi field protocol.

  • When Multi field positions are outside the bounds a problem notification will now be shown.

  • Fix for montage fields being overwritten by subsequent fields when only the prefix save option was enabled.

  • Fix for crash when importing a protocol by drag and drop.

  • Leica AFC will now find focus correctly when using water objectives.

  • Fix for application freeze during deconvolution when a ClearView library error occurs.

  • Dragonfly ports are now no longer visible when the Dragonfly is removed.

  • Fix for crash when attempting to stitch montage images created in a previous version of Fusion.

  • Fix for error when merging channels due to incompatible Tirf mode parameters when Tirf is not selected.

  • Fix for crash when deconvolution window is closed while a protocol with montage is running.

  • Fix for application freeze after changing the selected AOI of a sCMOS camera.

  • Fix for error message that was displayed when a montage was outside the bounds, but the stage bounds were unlocked.

  • Simulation beads of dummy camera now reflect the correct z plane when using Reference Z.

  • When a protocol is stopped the XY and Z stages will now return to their starting position.

  • Improved responsiveness when browsing the recent images list, when many images are present.

  • Do not allow the z scan centre position to move further once the min or max reaches the extents of the z device when setting up the scan range.

  • Fix for problem notification remaining when a camera is removed and re-added when using a multi-channel montage protocol.

  • Fix for multi field selection indicator disappearing when the selected multi field position is replaced with the current position.

  • Fix for crash when double click the remove device button on an active device in the device hub.

  • Fix for intermittent crash when aborting a protocol with montage, stitching and deconvolution enabled.

  • If the default camera can't be found on startup, pick the first camera as default.

Release 2.0.0.15 (hotfix)

14th August 2018

Bug Fixes
  • Fix for crash while saving TIFF files

  • Prevent configuration file corruption under some circumstances

  • Prevent failures related to invalid characters in channel/imaging mode names

  • Fix for issue that prevented ASI stage connection when only axis available.

Release 2.0

26th June 2018

Enhancements
  • SRRF-Stream™ Support

    • Dual Camera Support

    • Frame Count

    • Radiality Magnification

    • Temporal Analysis Type

    • Ring Radius

  • Montage Stitching using Imaris Stitcher

    • Phase Correlation Stitching Method when in High Quality Mode

      • Background subtraction

      • Gaussian filter width

    • Run both Stitching & Deconvolution during acquisition

    • Preview Montage Scans

  • Imaris Engine 9.0.3

  • Support for the Bitflow Axion camera card

  • Support for Nikon Ti2 XY Stage

  • Support for On/Off control of the Nikon Ti2 Dia Lamp

  • iXon default temperature set point updated to -50˚C

  • Improved auto-mapping functionality

    • New "optimise Blend Mapping" preference added

Bug Fixes
  • Delay at start of acquisition when large number of channels are present

  • Occasional crash when changing between confocal modes

  • No explanation was shown if the protocol was disabled due to not having any channels

  • Filename preferences were not remembered across restarts

Release 1.5

22nd December 2017

Enhancements
  • Leica DM6 Support

  • The Software Shuttering Mode feature on the Andor BOB device has been renamed to Brightfield Trigger Mode

  • Support for improved TIRF calibration, to better facilitate multi wavelength operation. Penetration Depth is now limited to a usable limit of 350nm

  • Image display waits for full texture rendering during playback

Bug Fixes
  • Fix for long delays occurring when switching display modes or starting acquisitions that occurred some time after viewing or acquiring a montage or multi field acquisition

  • Ensure that a temporary camera communication error will not cause a running protocol to abort

  • Fix for crash when running a Multi-field protocol with no

  • Time stamps are now being stored in the Image file correctly when a protocol is aborted early

  • Fix for repeated communication errors with an ASI Stage after an initial communication error

  • Improved ILE operation when changing imaging modes on the Dragonfly

  • Fix for Leica DMi8 connection when another FTDI device plugged in

  • Fix for several resource leaks which may cause a slow down with prolonged use

Release 1.4 

26th September 2017

Enhancements
  • Condensed Logging and Caching

  • Load, Write and Save Speed Improvements

  • Auto Save Improvements and Progress Updates

  • Tooltip Updates

  • Support Nikon Ti 2 Custom Objective

  • TIRF penetration limit changed to 100nm

  • Support iXon Life 

  • 3-fold ClearView-GPUTM Deconvolution speed up

Bug Fixes
  • Mapping changes not saved for images loaded from disk

  • Speed improvement when starting/stopping a merge channel protocol

  • Notification added when Dragonfly is initialising and shutting down

  • Camera ports selection re-added for dragonfly 

  • Stopped montage problem notification appearing during a non montage protocol

  • Defaulted file open type to "all supported"

  • Time Series interval now remembered if set to 0

  • XY missing problem notification removed when XY is connected

  • Colour of image channel now updates without changing the display mode

  • “Go To” on the XY scan panel no longer causes Fusion to hang when no scope or auto focus device is present

Release 1.3

16th August 2017

Enhancements
  • Inversion of separate stage axis

  • Nikon Ti2 Support

    • Nosepiece

    • Z Escape

    • Port

    • PFS

    • Filter Turret

Bug Fixes
  • Slowdown in Time and Finite Burst Protocols

  • Leica Light Path Sync Issue

Release 1.2

19th May 2017

Enhancements
  • Montage stitching using TeraStitcher

  • Andor BOB Device including:-

    • Support of Brightfield

    • Support of Analogue Piezo Z

About this release

For version information, please refer to About in Preferences.